Summary
For Correctional Foodservice Equipment – Jails, Prisons, Detention Centers
Facility Name: ____________________
Project / PO: ____________________
Date: ____________________
Reviewed By: ____________________
1. CONSTRUCTION & FRAME SECURITY
- Welded construction (no removable panels without tools)
- Fully enclosed bases; no cavities for hiding contraband
- Reinforced frames designed for correctional environments
- Continuous-weld seams (no gaps greater than 1/16")
- Heavy-gauge stainless steel where appropriate
- No exposed screws, fasteners, or hardware accessible to inmates
- All service access points require staff-only tools
- No detachable legs unless bolted or anchored
Notes: _________________________________________________
2. ANTI-LIGATURE DESIGN FEATURES
- Rounded corners on all exposed edges
- Recessed door handles and drawer pulls
- No protrusions that can support weight
- Sloped or curved tops where needed
- No lip or gap usable for tying materials
- Doors self-close or are secured when not in use
Notes: _________________________________________________
3. CONTROL PANEL SECURITY
- Vandal-resistant control panels
- Protective covers or locked housings on electronics
- Buttons and switches flush-mounted or recessed
- Controls designed for untrained or rotating labor
- No exposed wiring or removable knobs
- Temperature and cycle settings password- or lock-protected (if applicable)
Notes: _________________________________________________
4. HINGES, LATCHES & DOOR SECURITY
- Reinforced, tamper-proof hinges
- Hinges welded or secured with non-removable fasteners
- Lockable access panels (staff-only)
- Door gaskets concealed or reinforced
- Secure drawer slides that cannot be removed by hand
Notes: _________________________________________________
5. EQUIPMENT BASE, MOUNTING & MOBILITY
- Floor-mounted or fixed casters with locking plates
- No hidden cavities beneath or behind the unit
- Kick plates sealed to floor or fully welded
- Equipment cannot be easily moved without staff
- Anchoring points meet facility standards
Notes: _________________________________________________
6. INTERNAL COMPONENT SECURITY
- Internal fasteners require specialized or staff-only tools
- No loose parts or small removable components
- Mechanical components shielded or enclosed
- Electrical connections inaccessible without staff tools
- Motors, belts, and pumps protected from inmate access
Notes: _________________________________________________
7. CONTRABAND PREVENTION CHECKS
- No open cavities larger than 1/2" where contraband could be hidden
- No unsecured voids behind panels or service doors
- No hollow handles or removable shelving without staff tools
- Kick plates and backsplashes fully attached
- No removable drip trays unless staff-supervised
Notes: _________________________________________________
8. SANITATION & SAFETY REQUIREMENTS
- Meets NSF (National Sanitation Foundation) standards
- Surfaces smooth, cleanable, and corrosion-resistant
- No rust, dents, or damaged welds
- No sharp edges
- Supports ACFSA and HACCP sanitation protocols
- Fire suppression equipment compliant with UL 300 (if applicable)
Notes: _________________________________________________
9. OPERATIONAL USABILITY IN SECURE ENVIRONMENTS
- Simple interface suitable for rotating inmate labor
- Clear, durable labels or graphics
- Factory tamper-resistant package (if offered by manufacturer)
- Limited access to cycle adjustments or programming
- No detachable accessories unless staff-supervised
Notes: _________________________________________________
10. BRAND-SPECIFIC CORRECTIONAL PACKAGES
(If applicable — verify with manufacturer)
- Blodgett correctional package
- Middleby correctional series
- Caddy, JonesZylon, or IMC-Teddy correctional options
- Reinforced refrigeration hinges (True, Delfield, etc., when available)
- Tamper-proof dish machine kits (Champion, Hobart equivalents)
Notes: _________________________________________________