Chemical (Low-Temp) vs Heat (High-Temp) Dish Machines

Summary

Pros, Cons & How to Choose the Right System

Here is the same content, word-for-word, with all emojis removed and clean formatting only.

Commercial dish machines sanitize using one of two approved methods:

  • Chemical Sanitizing (Low-Temp)
  • Heat Sanitizing (High-Temp at 180°F)

Both are code-compliant when installed and operated correctly, but they perform very differently in the real world.

Chemical Sanitizing Dish Machines (Low-Temp)

These machines use chemical sanitizer (chlorine, quat, or iodine) in the final rinse instead of heat.

PROS

Lower Utility Requirements

  • No booster heater required
  • Lower electrical demand
  • Lower gas demand (if applicable)

Lower Upfront Equipment Cost

  • Machines are usually less expensive
  • No booster heater to purchase

Good for Older Buildings

  • Easier to retrofit where electrical or gas capacity is limited

Lower Water Temperature

  • Less scale formation from extreme heat
  • Reduced stress on internal components

Easier Installation

  • Simpler plumbing and electrical coordination

CONS

Ongoing Chemical Cost

  • Continuous expense for sanitizer
  • Requires:
    • Chemical pumps
    • Tubing
    • Test strips

Inspection Risk if Staff Are Not Trained

  • Wrong ppm = immediate violation
  • No test strips = automatic citation
  • Chemical pump failures can go unnoticed

Residue & Odor Potential

  • Chlorine smell
  • Quat film on dishes
  • Potential taste transfer to glassware

Environmental & Safety Concerns

  • Chemical handling risk
  • Eye/skin irritation if overdosed
  • Spill exposure liability

Less Effective on Heavy Grease Without Strong Pre-Rinse

  • Depends heavily on good staff scraping and pre-rinse behavior

Heat Sanitizing Dish Machines (High-Temp / 180°F)

These machines use high-temperature water (180°F final rinse) to sanitize instead of chemicals.

PROS

No Chemical Sanitizer Required

  • No daily chemical testing
  • No sanitizer smell or residue
  • No pump calibration

Strong Grease Cutting Power

  • Hot water dissolves fats and oils more effectively
  • Better for:
    • High-volume cooking
    • Heavy cookware
    • Institutional operations

Easier for Inspections

  • Inspectors simply verify:
    • Final rinse = 180°F
  • Less room for staff error than chemical ppm mixing

Better for Glassware Appearance

  • Fewer streaks when paired with proper rinse agent
  • No chemical film

Preferred in Healthcare & Federal Settings

  • Seen as more robust sanitation by regulators

CONS

Booster Heater Required

  • Adds:
    • Equipment cost
    • Utility coordination
    • Maintenance needs

Higher Electrical or Gas Demand

  • May require:
    • Panel upgrades
    • Gas service upsizing
    • Venting

More Scale Formation Without Water Treatment

  • High heat accelerates lime scale
  • Water softener becomes critical
  • Booster heater failure is common without softening

Higher Energy Consumption

  • More expensive per cycle than low-temp in many regions

Installation Is More Complex

  • Requires:
    • Final rinse verification
    • Thermal piping coordination
    • Pressure balancing

Side-by-Side Comparison Chart

Feature Chemical (Low-Temp) Heat (High-Temp)
Sanitizing Method Chemical ppm 180°F final rinse
Booster Heater ❌ Not required ✅ Required
Upfront Cost ✅ Lower ❌ Higher
Utility Load ✅ Lower ❌ Higher
Operating Cost ❌ Ongoing chemicals ✅ No chemicals
Inspection Risk ❌ High if ppm wrong ✅ Lower (temp check)
Grease Removal ⚠️ Moderate ✅ Strong
Smell/Residue Risk ❌ Possible ✅ None
Water Treatment Importance ✅ Important ✅✅ Critical
Best For Cafés, bars, small kitchens Restaurants, schools, hospitals

How to Know Which System Is Right for You

Choose Chemical (Low-Temp) if:

  • You have limited electrical/gas capacity
  • Your volume is moderate
  • Your staff is well-trained on test strips
  • You want lower upfront cost
  • You operate in a retrofit space

Choose Heat (High-Temp) if:

  • You run high volume
  • You produce heavy grease
  • You want simpler inspection verification
  • You operate in a hospital, school, or government facility
  • You want stronger overall wash performance

Top Failure Risks by System Type

Chemical System Failures

  • No test strips
  • Chemical pump failure
  • Over- or under-dosing
  • Staff unaware of required ppm
  • Empty sanitizer container

Heat System Failures

  • Undersized booster heater
  • No water softener
  • Incoming water too cold
  • Final rinse thermometer not working
  • Scale buildup on heating elements

Aldevra Selection Guidance

Neither chemical nor heat is “better” in every situation—the right choice depends on utilities, volume, labor consistency, water quality, and inspection risk tolerance.