Summary
Dish machines will eventually fail. What determines whether your kitchen stays open or gets shut down is not the machine—it’s your emergency response procedures, documentation, and manual warewashing readiness.
This guide gives you:
- Emergency protocols by failure type
- Immediate decision rules for managers
- Manual warewashing activation procedures
- Inspection-safe shutdown steps
- Reopening verification checklists
- Federal, hospital, and school continuity expectations
THE REALITY: DISHROOM FAILURES ARE OPERATIONAL EMERGENCIES
A dishroom emergency immediately impacts:
- Food safety
- Infection control
- Regulatory compliance
- Revenue continuity
- Patient/student safety
- Public trust
There is no grace period in most jurisdictions. If ware cannot be legally sanitized, food service must stop or shift to emergency operations immediately.
WHAT QUALIFIES AS A DISHROOM EMERGENCY?
Any of the following triggers emergency status:
- Final rinse temperature below 180°F (heat systems)
- Sanitizer ppm outside code range (chemical systems)
- Complete power loss to dish machine
- Booster heater failure
- Chemical injection failure
- Drain backup or floor sink overflow
- Sewer gas odors in dishroom
- Hood or ventilation failure
- Active water leak from dishwasher or booster
- Fire suppression activation
- Grease interceptor overflow
MANAGER DECISION RULE (STAY OPEN VS SHUT DOWN)
Immediately SHUT DOWN DISHWASHING if:
- Heat system cannot achieve 180°F
- Sanitizer ppm cannot be verified
- Drainage is backing up
- Chemical is empty with no replacement
- Electrical breaker continues to trip
- Hood system fails under steam load
- Fire system activates
You MAY continue limited operation ONLY if:
- 3-comp sink is fully operational
- Manual sanitizer ppm is verifiable
- Adequate air-drying space exists
- Emergency SOP is activated
- Manager authorizes in writing
IMMEDIATE SHUTDOWN PROCEDURE (MACHINE FAILURE)
When a failure occurs:
- Stop all rack processing immediately
- Turn off power to the dishwasher
- Shut off water supply (if leaking)
- Isolate chemical feed (if chemical failure)
- Post “OUT OF SERVICE” signage
- Notify manager and facilities/maintenance
- Initiate emergency manual warewashing (if remaining open)
- Log time and failure condition
- Contact authorized service provider
EMERGENCY MANUAL WAREWASHING ACTIVATION SOP
When dish machines are unusable:
- Activate 3-comp sink
- Wash with approved detergent
- Rinse with potable water
- Sanitize using:
- Heat (if allowed by sink setup), or
- Chemical ppm within code range
- Verify sanitizer with test strips
- Air-dry only
- Log emergency activation
- Use durable-only or disposable ware if volume exceeds sink capacity
HEAT SYSTEM FAILURE EMERGENCIES
Common Causes:
- Booster heater burnout
- Scale-coated heating elements
- Electrical overload
- Low incoming water temp
Immediate Actions:
- Transition to manual warewashing
- Verify sanitizer ppm
- Contact service immediately
- Do NOT continue running below temp
Any dishes washed below 180°F are not legally sanitized.
CHEMICAL SYSTEM FAILURE EMERGENCIES
Common Causes:
- Empty chemical container
- Failed injector pump
- Blocked injection line
- Incorrect sanitizer delivered
Immediate Actions:
- Stop machine
- Replace chemical container
- Re-prime system
- Verify ppm with test strips
- If ppm cannot be verified → manual warewashing only
DRAINAGE & SEWER EMERGENCIES
Drain failures are automatic shutdown triggers when:
- Water backs up under machines
- Floor sinks overflow
- Grease rises into rinse lines
- Sewer gas odor is present
Immediate Actions:
- Stop all washing
- Shut down discharge
- Post safety barricade
- Call plumbing service
- Ventilate area if sewer gas present
ELECTRICAL EMERGENCIES
Immediate shutdown required for:
- Repeated breaker tripping
- Electrical burning odor
- Control panel faulting
- Motor overheating
Immediate Actions:
- Lockout/tagout
- Shut down water and booster
- Call licensed electrician
- Do not bypass safety devices
FIRE SYSTEM & SUPPRESSION EMERGENCIES
If fire suppression activates:
- Shut down all equipment
- Evacuate per fire plan
- Call facilities & fire systems contractor
- Do NOT resume dish operations until:
- Suppression chemicals cleared
- Hood system verified
- Electrical cleared
INSTITUTIONAL CONTINUITY REQUIREMENTS (VA, HOSPITALS, SCHOOLS)
These facilities must maintain:
- Redundant manual warewashing capacity
- Disposable ware stock for emergencies
- Facilities engineering escalation chain
- Infection control notification protocols
- Environmental services coordination
Dishroom shutdowns in these environments are clinical risk events—not just kitchen issues.
REOPENING A DISHWASHER AFTER AN EMERGENCY (MANDATORY PROCESS)
Before resuming operation:
- Service documentation completed
- Machine re-powered safely
- Booster heater verified
- Final rinse temp verified ≥ 180°F (if heat)
- Sanitizer ppm verified (if chemical)
- Drain tested under load
- Hood operational
- No leaks present
- Manager signs reopening log
EMERGENCY DOCUMENTATION REQUIRED FOR INSPECTION DEFENSE
Every emergency event must log:
- Date/time of failure
- Type of failure
- Immediate actions taken
- Service call time
- Temporary warewashing method used
- Reopening verification
These logs protect against:
- Closure orders
- Retroactive citations
- Liability claims
WHY KITCHENS GET CLOSED AFTER EMERGENCIES
Most forced closures occur because:
- Staff keeps washing below temp
- No ppm testing during chemical failure
- Towel drying used during manual washing
- Failure not logged
- No service documentation
- Inspector arrives mid-failure
MANAGER EMERGENCY RESPONSIBILITY SUMMARY
Managers must:
- Authorize shutdown or emergency operations
- Verify manual sanitizing
- Assign log responsibility
- Contact service providers
- Approve reopening
- Brief staff on restrictions
Dishroom emergencies cannot be delegated without authority.
DON’T LET A SINGLE FAILURE SHUT YOU DOWN