Summary
Inspector-Style Decision Tool
Rule: If you hit a NO on any Critical Pass/Fail item, the dishroom will not pass inspection—regardless of how nice the equipment is.
STEP 1 — Is Legal Warewashing Even Possible?
Answer YES to ALL:
☐ Commercial NSF-rated dishwasher installed OR three-compartment sink available
☐ Three-compartment sink present (even if dishwasher exists)
☐ Separate hand sink in dishroom
☐ Hot water available at all sinks
☐ No residential equipment used
ALL YES → Go to STEP 2
ANY NO → WILL NOT PASS
STEP 2 — Can It Actually Sanitize?
If High-Temp Machine:
☐ Final rinse reaches 180°F
☐ Booster heater installed & functioning
☐ Thermometer visible and working
If Chemical (Low-Temp):
☐ Sanitizer connected and pumping
☐ Correct test strips available
☐ Required ppm range posted
ALL YES → Go to STEP 3
ANY NO → WILL NOT PASS
STEP 3 — Is Drainage Legal & Protected?
☐ Dishwasher drains indirectly through a floor sink
☐ Air gap present
☐ No direct sewer connections
☐ No wastewater backing up
☐ No standing water under machine
ALL YES → Go to STEP 4
ANY NO → WILL NOT PASS
STEP 4 — Are Dirty & Clean Zones Fully Separated?
☐ Dirty dish drop zone exists
☐ Scrape & pre-rinse station before machine
☐ Clean outfeed table after machine
☐ Clean dishes never cross into dirty zone
☐ Staff traffic is one-directional (dirty → clean)
ALL YES → Go to STEP 5
ANY NO → WILL NOT PASS
STEP 5 — Is Air-Drying Possible Without Towel Use?
☐ Dedicated air-dry racks or tables
☐ Adequate space for drying during peak
☐ No towel drying practiced
☐ No wet stacking
ALL YES → Go to STEP 6
ANY NO → WILL NOT PASS
STEP 6 — Is Clean Storage Legal?
☐ All clean dishes stored off the floor
☐ Storage is NSF-approved
☐ No clean storage under plumbing
☐ No splash exposure from dirty side
ALL YES → Go to STEP 7
ANY NO → WILL NOT PASS
STEP 7 — Are Test Strips & Logs Present?
☐ Test strips match sanitizer type
☐ Stored at the machine/sink
☐ Not expired
☐ Daily temp/chemical logs in use
ALL YES → Go to STEP 8
ANY NO → HIGH RISK OF FAILURE
(Some inspectors allow correction on-site, some do not.)
STEP 8 — Is Waste Handling Compliant?
☐ Scrap collected at scrape station
☐ Trash/compost covered
☐ Grease interceptor installed if required
☐ Floor sink strainers in place
ALL YES → Go to STEP 9
ANY NO → HIGH RISK OF FAILURE
STEP 9 — Is Water Treatment Installed (If Required)?
☐ Water hardness tested
☐ Softener installed where hardness exceeds limits
☐ Sediment filter installed
☐ Delime plan in place
YES → Go to STEP 10
NO → WILL LEAD TO FUTURE FAILURE & WARRANTY RISK
STEP 10 — Is Emergency Backup Available?
☐ Three-comp sink usable if machine fails
☐ Sanitizer available
☐ Test strips available
☐ Emergency SOP posted
ALL YES → SHOULD PASS INSPECTION
ANY NO → MAY BE SHUT DOWN DURING FAILURE
FINAL RESULTS INTERPRETATION
Fast “One-Page” Critical Pass Items (For Sales & Design)
Your dishroom WILL NOT PASS without:
- Commercial NSF dishwasher or 3-comp sink
- Separate hand sink
- Legal indirect drain & air gap
- Proper sanitizing (180°F or correct ppm)
- Dedicated air-dry space
- Clean storage off the floor
- Test strips (if chemical)
- Dirty-to-clean separation
Aldevra Inspector-Aligned Guiding Rule
If you cannot visually trace food-contact items from dirty drop → wash → sanitize → air-dry → clean storage without crossing paths, the dishroom is not compliant.