CRITICAL FAILURES (Immediate Shutdown Risk)
☐ No final rinse at 180°F
☐ No sanitizer ppm verification
☐ No indirect drain / missing air gap
☐ Wastewater backing up
☐ Hand sink blocked or missing
☐ No functioning three-comp sink when required
☐ Chemical pumps not working
☐ No test strips available
☐ Grease interceptor not tied into system
Correction Required By: ___________________
MAJOR FAILURES (Inspection Citation Likely)
☐ No water softener on hard water
☐ Booster heater undersized
☐ No condensation hood over hood machine
☐ No air-dry space
☐ Clean storage under plumbing
☐ Drain strainers missing
☐ Floor not sloped to drain
☐ No PM logs posted
MINOR FAILURES (Operational Risk)
☐ Missing signage
☐ Racks damaged or rusted
☐ Inadequate drying racks
☐ No splash guards at pre-rinse
☐ No chemical SDS binder
☐ Missing thermometers
☐ Inadequate lighting in dishroom
REINSPECTION CLEARANCE
☐ All critical items corrected
☐ All major items corrected
☐ All minor items corrected
☐ Re-test completed
☐ Documentation updated
☐ Staff retrained
Reinspection Date: ____________________
Approved By: _________________________