1. Project & Contact Info

Project Name: ____________________________________
Site Address: ____________________________________
City / State / Zip: _______________________________
Owner / Licensee: ________________________________

Primary Site Contact (day-of install):
Name: _________________________
Phone: _________________________
Email: _________________________

General Contractor (if any): ______________________
Target Install Date(s): ___________________________

2. Electrical Readiness

2.1 Service & Panels

☐ Main electrical service is active and turned on
☐ Adequate service capacity for new kitchen load (per electrician)
☐ Required voltage and phase available (check all that apply):
☐ 120V single-phase
☐ 208/240V single-phase
☐ 208/240V three-phase
☐ 480V three-phase
☐ Electrical panels are installed, labeled, and accessible
☐ Spare breaker spaces available (or new subpanel installed if needed)

2.2 Dedicated Circuits & Outlets

For each major piece of equipment, confirm:

Equipment Required Voltage / Phase Required Amps Dedicated Circuit Installed? Receptacle Matches Plug?
__________ ______ ______ ☐ Yes ☐ No ☐ Yes ☐ No
__________ ______ ______ ☐ Yes ☐ No ☐ Yes ☐ No
__________ ______ ______ ☐ Yes ☐ No ☐ Yes ☐ No

☐ All outlets are located within manufacturer’s specified distance of equipment
☐ GFCI protection installed where required (wet or prep areas)
☐ No extension cords planned for fixed equipment

2.3 Verification

☐ Licensed electrician has reviewed equipment schedule and confirmed readiness

Name: _________________________
License #: _______________
Signature: _____________________
Date: _____________________

3. Plumbing, Water & Drains

3.1 Water Supply

☐ Potable water supply is active and tested
☐ Cold and hot water lines are run to all required fixtures
☐ Incoming water pressure verified within equipment requirements
☐ Water treatment / filtration installed where needed:
☐ Combi oven
☐ Steam equipment
☐ Ice or beverage equipment
☐ Kettles

3.2 Plumbing Fixtures

☐ 3-compartment sink installed and connected
☐ Hand sinks installed in required locations (prep, production, packaging)
☐ Mop sink or service sink installed and accessible

3.3 Floor Drains & Wastewater

☐ Floor drains installed where needed (dish area, kettle area, walk-ins if required)
☐ Floors slope properly to drains—no standing water
☐ Grease interceptor installed (if required by code)

3.4 Verification

☐ Licensed plumber has reviewed equipment schedule and confirmed readiness

Name: _________________________
License #: _______________
Signature: _____________________
Date: _____________________

4. Gas (If Applicable)

☐ Gas service is active and pressure verified
☐ Gas piping sized for total connected load
☐ Gas shutoff valves installed and accessible for each appliance
☐ Quick-disconnects and flex connectors installed where required
☐ Combustion air and venting verified (per mechanical contractor)

5. HVAC, Hoods & Ventilation

☐ Required hood type installed (check all that apply):
☐ Type I (grease and smoke)
☐ Type II (heat and steam)
☐ Hood size and location match cooking equipment under it
☐ Fire suppression system installed and certified (UL 300)
☐ Makeup air unit installed and balanced
☐ Exhaust fans operational and tested
☐ HVAC system sized to handle added heat load from kitchen
☐ Temperature and humidity control appropriate for:
☐ Chocolate room
☐ Gummy/candy cooling
☐ Packaging area

Balance Report (if available):
☐ Air balance completed
Date: __________
Performed by: ___________________________

6. Space, Clearances & Access

6.1 Equipment Footprint

☐ Wall/floor finishes installed in all equipment locations
☐ Floors are smooth, non-porous, and cleanable

For each major item, verify:

Equipment Location Marked on Floor? Required Clearance Met? (sides / back / top)
__________ ☐ Yes ☐ No ☐ Yes ☐ No
__________ ☐ Yes ☐ No ☐ Yes ☐ No
__________ ☐ Yes ☐ No ☐ Yes ☐ No

☐ Doorways and corridors wide enough for equipment delivery (measure largest piece + pallet if needed)
☐ Path from loading area to final location is free of steps/obstructions (or ramps are in place)

6.B Sanitation Zones

☐ 3-comp sink, hand sinks, and dishmachine areas have adequate clearance for use and maintenance
☐ Drying racks or shelving available near sink/dish area
☐ No cross-traffic of dirty dishes through packaging zone

7. Security, Data & Compliance (Cannabis-Specific)

☐ Security system installed and active
☐ Cameras cover all required areas (production, storage, waste, entries/exits)
☐ NVR / video storage configured for required retention period
☐ Secure cannabis storage (room or cage) installed and lockable
☐ Access control installed (keys, keypad, or badge system)
☐ Seed-to-sale system (e.g., Metrc / BioTrack) in place or scheduled
☐ Network and data drops available at required stations (QA, packaging, office)

8. Pre-Install Photos & Documentation

Ask the customer to attach or upload:
☐ Photos of each utility connection point (electrical, water, gas) for major equipment
☐ Photos of hood and fire suppression system
☐ Photos of floor drains and sinks
☐ Floor plan or sketch with equipment locations marked

Optional:
☐ Most recent health department report (if existing facility)
☐ Most recent fire inspection report

9. Final Readiness Confirmation

Site Contact Certification
I confirm that, to the best of my knowledge, the utilities and site conditions described in this checklist are accurate and ready for equipment installation on the scheduled date(s).

Name: ___________________________
Title: ___________________________
Signature: _______________________
Date: ___________________________